Automotive cable
Application Product Construction Technical Data Wires & Cables FLRYDY Features ü Low-tension electric wire for Automobiles. ü Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits. ü Flame retardant ü Highly resistant against acids, lyes, Petrol and diesel. ü Flexible conductors with PVC thin wall insulation with increased mechanical strength. ü Extra flexibility. Wires & Cables Catalogue No 855 Nominal Cross- Section No. of Strands Diameter of Single wire max. Conductor Construction Conductor Diameter Nom. Cable Overall Diameter Weight Approx. Nom. Insulation Wall Thickness Nom. 2 mm nos. mm kg/km mm Part Number mm mm 0.75 1.0 1.5 Standard Length* 500 500 500 mtrs ü Temperature Range : 0 0 - 40 C to +105 C (3000 Hours) 2 ü Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm 2 5kV (r.m.s.) for cables ≥ 0.5 mm ü FL : Automotive cable ü R : Reduced wall thickness ü Y : PVC ü D : Copper wire spiral Shield ü Y : PVC ü Standard : ISO 6722, Class B ü Insulation : PVC, according to ISO 6722,Class B ü Screen: ATC braiding ü Sheath: PVC, Lead free Class B ü Colour : As per customer order. ü Single core E-Cu ETP1 according to DIN 13602, bare conductor ü Conductor : Soft-annealed electrolytic Copper 85508XXYY 85510XXYY 85513XXYY Siechem FLRYDY RoHS 123 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 2.7 2.9 3.2 0.3 0.3 0.3 1.2 1.35 1.7 0.21 0.21 0.26 24 32 30 Ω/km 24.7 18.5 12.7 Sheath wall Thickness mm 0.3 0.3 0.3 Max. Conductor Resistance 0 at 20 C Amps 20 24 30 20 23 29 Current Carrying Capacity Note : XX*YY* : Please add last two digits in the part number as per the colour code given hereunder replacing XX YY while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 0 0 ü Current Carrying capacity given is for the maximum conductor operating temperature of 105 C and ambient air temperature of 40 C. ü * Other length as per Customer order. * Siechem Wires & Cables Meet EU RoHS Directive AS 9100 ISO 45001 ISO 9001 ISO 14001 IATF 16949
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=