Automotive cable
Application Product Construction Technical Data Wires & Cables 2D View Siechem Auto 85 TW Class A RoHS 0 0 ü Temperature Range: -40 C to +85 C (3000 Hours) ü Standard : ISO 6722 Class A (Thin wall) 2 ü Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm 2 5kV (r.m.s.) for cables ≥ 0.5 mm Auto 85 TW Features ü Low-tension electric wire for Automobiles. ü Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits. ü Unliay conductor stranding ü Reduced diameter wall thickness ü Saving of insulation material, resulting in substantial weight reduction ü Conductor : Soft / annealed Plain Copper according to ISO 6722 (Symmetrical) ü Insulation : PVC with properties according to ISO 6722 class A, Lead free(thin wall) ü Colour : As per customer order ü Cable construction according to ISO 6722, Class A ü Single core, Single layer insulation Wires & Cables Nominal Cross- Section No. of Strands Diameter of Single wire max. Conductor Construction Conductor Diameter max. Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness Nom. 2 mm nos. mm mtrs kg/km mm Standard Length* Part Number mm mm Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 o o ü Current Carrying capacity given is for the maximum conductor operating of 85 C and ambient air temperature of 40 C. ü Cables are also available in dual colored insulation ü * Other length as per Customer order. * Max. Conductor Resistance 0 at 20 C Ω/km Catalogue No A823 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 0.35 0.50 0.75 1 1.5 2 2.5 3 4 5 6 10 16 25 0.25 0.28 0.30 0.30 0.30 0.35 0.35 0.40 0.40 0.40 0.40 0.60 0.65 0.65 1.40 1.60 1.90 2.10 2.40 2.80 3.00 3.40 3.70 4.20 4.30 6.00 7.90 9.40 54.4 37.1 24.7 18.5 12.7 9.42 7.60 6.15 4.71 3.94 3.14 1.82 1.16 0.743 2000 2000 2000 2000 2000 2000 2000 1000 1000 1000 1000 1000 1000 1000 7 19 19 19 19 19 37 37 37 37 37 63 105 154 0.27 0.19 0.24 0.27 0.33 0.38 0.28 0.34 0.38 0.43 0.45 0.46 0.46 0.46 5 6 9 11 16 23 26 34 42 53 60 106 176 249 0.90 1.10 1.30 1.50 1.80 2.00 2.20 2.40 2.80 3.10 3.40 4.50 5.80 7.20 Class A B C D E F G H o o o o o o o o +85 C +100 C +125 C +150 C +175 C +200 C +225 C +250 C Temperature o from -40 C to Cables confirming to the below categories are also available according to customer requirement Conductor Configuration : Symmetrical, Asymmetrical, Flexible Insulation thickness : Standard, Thin wall & Ultra thin wall ISO 6722 Temperature Class Rating : A82305XX A82306XX A82308XX A82310XX A82313XX A82314XX A82316XX A82317XX A82319XX A82321XX A82323XX A82327XX A82328XX A82330XX 74 Current Carrying Capacity Amps 9 11 15 18 23 28 32 37 44 50 54 78 108 201 Siechem Wires & Cables Meet EU RoHS Directive AS 9100 ISO 45001 ISO 9001 ISO 14001 IATF 16949
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=