Automotive cable

Application Product Construction Technical Data Wires & Cables Siechem Auto 125X-B / FLR2X-B RoHS Auto 125X-B / FLR2X-B Features ü Low-tension electric wire for automobiles. ü Used in motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits. ü Flame retardant ü Highly resistant against acids, lyes, petrol and diesel. ü Extra flexibility. Wires & Cables Catalogue No 843 Nominal Cross- Section No. of Strands Diameter of Single wire Max. Conductor Construction Conductor Diameter Max. Cable Overall Diameter Weight Approx. Max. Insulation Wall Thickness Nom. 2 mm nos. mm kg/km mm Part Number mm mm Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 o o ü Current Carrying capacity given is for the maximum conductor operating of 125 C and ambinet air temperature of 40 C. ü * Other length as per Customer order. * 0.35 0.5 0.75 1 1.5 2 2.5 3 4 6 Standard Length* 500 500 500 500 500 500 500 500 500 500 mtrs ü Temperature Range : 0 0 - 40 C to +125 C (3000 Hours) 2 ü Test Voltage: 3kV (r.m.s.) for cables < 0.5 mm 2 5kV (r.m.s.) for cables ≥ 0.5 mm ü Standard : ISO 6722,Class C ü FL : Automotive Cable ü R : Reduced wall Thickness ü 2X : Cross Linked PE ü B : Asymmetrical ü Insulation : PE-X,with properties according to ISO 6722, Class C ü Colour : As per customer order. ü Single core E-Cu ETP1 according to DIN 13602, bare conductor ü Conductor : Soft-annealed electrolytic copper 92 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 1.4 1.6 1.9 2.1 2.4 2.8 3.0 3.4 3.7 4.3 0.25 0.28 0.30 0.30 0.30 0.35 0.35 0.40 0.40 0.40 0.21 0.21 0.21 0.21 0.26 0.31 0.26 0.31 0.31 0.31 0.90 1.10 1.30 1.50 1.80 2.00 2.20 2.40 2.80 3.40 12 16 24 32 30 28 50 44 56 84 5 6 9 12 17 23 26 33 41 62 Max. Conductor Resistance 0 at 20 C 54.4 37.1 24.7 18.5 12.7 9.42 7.60 6.15 4.71 3.14 Current Carrying Capacity Ω/km Amps 12 15 20 24 30 37 42 49 58 75 84305XX 84306XX 84308XX 84310XX 84313XX 84314XX 84316XX 84317XX 84319XX 84323XX Siechem Wires & Cables Meet EU RoHS Directive AS 9100 ISO 45001 ISO 9001 ISO 14001 IATF 16949

RkJQdWJsaXNoZXIy NDgyMjA=