Drone_Cable_Catalogue
Product Construction Wires & Cables Application Features Siechem Coaxial LMR 100A Cable Technical Data www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Siechem Coaxial LMR 100A Cable ü Operating temperature : -40°C to +85°C Tensile strength : 6.8Kg ü Impedance : 50 Ω ü Nom. Capacitance : 101.1 pF/m ü Velocity of propagation : 66% ü ü Min. Bending radius : i) Static : 5 x Cable OD. ii) Dynamic : 10 x Cable OD. ü Flat plate crush : 10 Kg/mm. Cut off Frequency : 90 GHz. ü Dielectric constant : 2.30 NA. ü Time Delay : 5.05 ns/m. ü Inductance : 0.25 µH/m. ü Shielding Effectiveness : >90 dB. ü Voltage withstand : 500 V DC. ü Jacket spark : 2000 Volts RMS. ü Peak power : 0.6 kW ü LMR 100 Automotive Cables ü Conductor : Solid Bare Copper Clad Steel. Insulation : Solid Polyethylene. ü Core Identification : Natural or (as per ü customer order). Shield : Double Shield Aluminium Tape ü (Duofoil) - (100% Coverage). Braid : ATC (80% Coverage). ü Outer sheath : PVC - Black. ü ü Used for transmission of high-frequency RF signals with low loss. Ensures stable 50 Ω impedance for reliable signal ü performance. Suitable for data transmission and networking ü systems. Progress throughResearch R TUV ** Certifications Approvals Accreditations INTERNATIONAL ACCREDITATION SERVICE R ü Compact, lightweight design. High flexibility. ü Low signal attenuation. ü High EMI protection. ü Excellent shielding effectiveness. ü Easy installation. ü RF connector compatible. ü High-frequency capability. ü 2D View Catalogue No. C977 Part Number Conductor Construction C997A900004 Nos. 1 Nos. 1 Nom. Cross Section area No. of Core mm 0.17 No. of Strands mm 0.46 Conductor Diameter (Nom.) Dia. Over Insulation (Nom) mm 1.52 Dia. Over Shield (Nom.) mm 1.65 Overall outer Diameter (Max.) mm 2.79 Dia. Over Braid (Nom.) mm 2.11 Weight Approx. Conductor Resistance at 20°C (Nom.) Kg/Km 14 Ω /Km 266 30 12.9 0.230 ** We have obtained various approvals, accreditations, and certifications — some of which may not be relevant to this catalog. Frequency (MHz) Max. Attenuation (dB/100m) Ag. Power kW 50 16.7 0.180 150 29.4 0.100 220 35.8 0.083 450 51.9 0.057 900 74.9 0.039 1500 98.7 0.029 1800 109.0 0.027 2000 115.5 0.025 2500 130.6 0.022 5800 210.3 0.013 Insulation Thickness (Nom) mm 0.40 Sheath Thickness (Nom.) mm 0.38 Braid Thickness (Nom.) mm 0.1 5
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=