Indian Railway Cables

Application Product Construction Technical Data Features ü Conductor : Annealed Tinned Flexible Copper Conductor, Class 5. ü Insulation : EBXL - EPDM 120ºC ü Outer sheath : Electron Beam Cross Linked Polyolefin Black colour. ü Temperature range : Operating temp :-40ºC to +120ºC. ü Rated voltage : 600/1000V ü Short circuit temperature : +280ºC. ü Test voltage : 1.5kV for 5 mins ü Bending radius : 4D for cables for fixed installation 5D for cables for flexible installation ü Specification : EDTS 132 Rev-C (DS-3) ü Limited fire hazard type ü Minimum flame spread ü Low smoke emission ü Limited toxic fume emission ü Resistant to mineral oil, diesel, etc. Multi Core Unscreened 600/1000V Grade Thin Walled Flexible EBXL Cables for Coaching Stock Application Catalogue No. 267 Siechem 600/1000V 4C x 1.5 Sq. mm EBXL - HR 120ºC Cable www.siechem.com All information given are in good faith. Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any other compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 2670602 2670802 2671002 2671302 2670603 2670803 2671003 2671303 2670604 2670804 2671004 2671304 2C x 0.50 2C x 0.75 2C x 1.0 2C x 1.5 3C x 0.50 3C x 0.75 3C x 1.0 3C X 1.5 4C x 0.50 4C x 0.75 4C x 1.0 4C x 1.5 19 x 0.18 24 x 0.20 32 x 0.20 30 x 0.25 19 x 0.18 24 x 0.20 32 x 0.20 30 x 0.25 19 x 0.18 24 x 0.20 32 x 0.20 30 x 0.25 6.2 ± 0.30 6.6 ± 0.30 7.5 ± 0.30 7.8 ± 0.30 6.8 ± 0.30 7.0 ± 0.30 7.9 ± 0.30 8.3 ± 0.30 7.4 ± 0.30 7.7 ± 0.30 8.8 ± 0.30 9.1 ± 0.30 40.1 26.7 20.0 13.7 40.1 26.7 20.0 13.7 40.1 26.7 20.0 13.7 51 67 77 89 59 71 91 109 76 88 114 135 Cable Outer Diameter (mm) Cable Weight Approx. (Kg/Km) Max. Resistance of Conductor 0 at 20 C (Ohm/km) Part Number ü Thin walled Flexible EBXL Cables for Passenger coaches, AC/DC EMU, BG, AC EMU & MEMU coaching stock. Colour Code : 2 Core - Brown, White, 3 Core - Brown, White & Green / Yellow & 4 Core - Black, Brown, White & Green / Yellow No. of Wires x Single Wire dia (Nom) (Nos / mm) No.of core x Nominal Cross Sectional Area (Nos x sqmm) Wires & Cables 17 ** We have obtained various approvals, accreditations, and certifications — some of which may not be relevant to this catalog. Progress throughResearch R TUV ** Certifications Approvals Accreditations INTERNATIONAL ACCREDITATION SERVICE R 2D View

RkJQdWJsaXNoZXIy NDgyMjA=