Marine cable

Wires & Cables www.siechem.com TABLE 34 : SINGLECORE CABLES WITH SCREEN OVERSHEATH, 600V Application Product Construction Technical Data Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Features Fire retardant Halogen free Temperature Range Rated Voltage (U /U) o Test Voltage Bending Radius(Min) Flexing Fixed Specification 0 0 : - 65 C to +120 C : 600 V : 1.5 kV : 10 x Cable Diameter : 4 x Cable Diameter : EED 50-12 (Rev 3) Conductor Insulation Outer Sheath Braiding : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : 8130 -1984 : Electron Beam Cross Linked Dual layer Polyolefin Compound : Electron Beam Cross Linked Polyolefin Compound : Annealed Tinned Copper braid (95% coverage) Siechem Singlecore Cables with Screen Oversheath Marine Cable 127 N6145021262 N6145021263 N6145021264 N6145021265 N6145021266 N6145021267 N6145021268 1C x 0.5 1C x 0.75 1C x 1.0 1C x 1.5 1C x 2.5 1C x 4 1C x 6 4.9 5.1 5.3 5.5 6.0 7.2 7.8 40.1 26.7 20.0 13.7 8.21 5.09 3.39 14.0 17.0 20.0 29.0 39.0 48.0 70.0 49 53 57 63 82 121 155 Part Number Number of Cores 2 and mm Per Conductor Overall Diameter in Approx.(mm) Approx. Weight of Cable (Kg/Km) Max. Conductor Resistance 0 at 20 C ( Ω /km) Current Rating 0 (Air ambient 50 C) at 50-60Hz Amps No. of Wires (Typical Value) x Single Wire dia (Max.) 16/0.21 24/0.21 32/0.21 30/0.26 50/0.26 56/0.31 84/0.31 Catalogue No EED 50-12 (R3) C34 AS 9100 ISO 45001 ISO 9001 ISO 14001 IRS DGQA

RkJQdWJsaXNoZXIy NDgyMjA=