Marine cable

Wires & Cables TABLE 36 : SINGLECORE CABLES, LOW CAPACITANCE, 600V Siechem Singlecore Cables, Low Capacitance Marine Cable Application Product Construction Technical Data Power, Lightning, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Features Fire retardant Halogen free Temperature Range Rated Voltage (U /U) o Test Voltage Bending Radius(Min) Flexing Fixed Specification 0 0 : - 65 C to +120 C : 600 V : 1.5 kV : 10 x Cable Diameter : 4 x Cable Diameter : EED 50-12 (Rev 3) Conductor Insulation Braiding Separator Tape Outer Sheath : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with IS : 8130 -1984 : Electron Beam Cross Linked Dual layer Polyolefin Compound : Annealed Tinned Copper braid (95% coverage) : Polyester Tape : Electron Beam Cross Linked Polyolefin Compound Part Number Number of Cores 2 and mm Per Conductor Overall Diameter in Approx.(mm) Approx. Weight of Cable (Kg/Km) Max. Conductor Resistance 0 at 20 C ( Ω /km) Current Rating 0 (Air ambient 50 C) at 50-60Hz Amps No. of Wires (Typical Value) x Single Wire dia (Max.) N6145021282 N6145021283 N6145021284 N6145021285 1C x 1 1C X 1 1C x 1 1C x 2.5 32/0.21 32/0.21 32/0.21 50/0.26 7.3 8.3 13.0 6.8 20.0 20.0 20.0 8.21 20.0 20.0 20.0 39.0 70 115 240 74 www.siechem.com 129 Catalogue No EED 50-12 (R3) C36 AS 9100 ISO 45001 ISO 9001 ISO 14001 IRS DGQA

RkJQdWJsaXNoZXIy NDgyMjA=