Marine cable

Wires & Cables 2 TABLE C2 : Multicore Cables - Unscreened 0.35mm Siechem Multicore - Unscreened Marine Cables Application Product Construction Technical Data Power, Lighting, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Features Limited Fire Hazard Halogen free Temperature Range Rated Voltage (U /U) o Test Voltage Bending Radius Flexing Fixed Specification 0 0 : - 29 C to +85 C : 600 V : 1.5 kV : 10 x Cable Diameter : 4 x Cable Diameter : NES 525 Conductor Insulation Laying up Outer Sheath : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound : Limited Fire Hazard complying with NES 518 Material . 743-0462 743-0463 743-0464 743-0465 743-0466 743-0467 743-0468 3C X 0.35 7C X 0.35 14C x 0.35 19C x 0.35 24C X 0.35 37C X 0.35 44C x 0.35 4.25 5.15 6.70 7.25 8.50 9.55 10.80 33 56 95 125 155 215 280 2.48 3.45 5.08 5.75 6.90 8.05 9.20 1.0 1.0 1.0 1.0 1.1 1.1 1.2 5.40 6.45 8.10 8.75 10.10 11.45 12.80 Part Number 2 Number of Cores and mm Per Conductor Outer Diameter in (mm) Total Weight Kg/Km approx. Nominal Diameter Over Cores (mm) Radial Thickness of Sheath (mm) Max. Conductor 0 Resistance at 20 C ( Ω /km) Min Max 58.9 58.9 58.9 58.9 58.9 58.9 58.9 www.siechem.com 138 Catalogue No NES 525 C2 AS 9100 ISO 45001 ISO 9001 ISO 14001 IRS DGQA

RkJQdWJsaXNoZXIy NDgyMjA=