Marine cable
Part Number 2 Number of Cores and mm Per Conductor Outer Diameter in (mm) Total Weight Kg/Km approx. Nominal Diameter Over Cores (mm) Radial Thickness of Sheath (mm) Max. Conductor 0 Resistance at 20 C ( Ω /km) Min Max Wires & Cables 2 TABLE C5 : Multicore Cables - Unscreened 1.5mm Siechem Multicore - Uncreened Marine Cable Application Product Construction Technical Data Power, Lighting, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Features Limited Fire Hazard Halogen free Temperature Range Rated Voltage (U /U) o Test Voltage Bending Radius Flexing Fixed Specification 0 0 : - 29 C to +85 C : 600 V : 1.5 kV : 10 x Cable Diameter : 4 x Cable Diameter : NES 525 Conductor Insulation Laying up Outer Sheath : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound : Limited Fire Hazard complying with NES 518 Material . 743-0484 743-0485 743-0486 743-0487 743-0488 2C x 1.5 3C x 1.5 7C x 1.5 14C x 1.5 24C x 1.5 3.80 4.10 5.70 8.40 11.40 1.0 1.0 1.0 1.1 1.3 5.60 5.90 7.40 10.15 13.40 6.80 7.10 8.70 11.80 15.20 58 75 145 275 460 14.7 14.7 14.7 14.7 14.7 www.siechem.com 141 Catalogue No NES 525 C5 AS 9100 ISO 45001 ISO 9001 ISO 14001 IRS DGQA
Made with FlippingBook