Marine cable

Part Number 2 Number of Pairs and mm Per Conductor Outer Diameter in (mm) Total Weight approx. (Kg/Km) Nominal Diameter Over Cores (mm) Radial Thickness of Sheath (mm) Max. Conductor 0 Resistance at 20 C ( Ω /km) Min Max Wires & Cables 2 TABLE C11 : Multipair Cables - Individually Screened 0.35mm Siechem MulticoreCables,Cores IndividuallyScreenedMarineCable Application Product Construction Technical Data Power, Lighting, Control & Communication and Instrumentation circuits in surface ships and submarines. Used in fuel and lubrication oils, hydraulic fluids and water surfaces. Ship systems & equipments and weapon systems & equipments. Features Limited Fire Hazard Halogen free Temperature Range Rated Voltage (U /U) o Test Voltage Bending Radius Flexing Fixed Specification 0 0 : - 29 C to +85 C : 600 V : 1.5 kV : 10 x Cable Diameter : 4 x Cable Diameter : NES 525 Conductor Insulation Cores laid up Individual Screen Pairs laid up Outer Sheath : Circular Electroplated, annealed tinned flexible copper wire (Class 5) complying with BS : 6360 : Limited Fire Hazard Compound : Annealed Tinned Copper braid (95% Coverage) : Limited Fire Hazard complying with NES 518 Material . 743-0520 743-0521 743-0522 743-0523 1P x 0.35 3P x 0.35 5P x 0.35 7P x 0.35 50 130 200 260 6.30 10.40 12.50 13.50 4.80 8.80 10.65 11.55 3.20 7.02 8.78 9.75 1.0 1.1 1.2 1.2 58.9 58.9 58.9 58.9 www.siechem.com 147 Catalogue No NES 525 C11 AS 9100 ISO 45001 ISO 9001 ISO 14001 IRS DGQA

RkJQdWJsaXNoZXIy NDgyMjA=