Rolling Stock
Wires & Cables Application Product Construction Technical Data 0 Siechem BS EN 50306-4 1P Multi Core, 300V AC, 450V DC, EBXL 90 C Rolling Stock Cable Part Number Cable Weight (Kg/Km) approx. Outer Diameter (mm) Max. Core Diameter (mm) Min. Sheath Thickness (mm) ü Conductor : Finely Stranded Annealed Electro Tinned Copper, (Unilay * ) ü Insulation : Cross Linked Ethylene Copolymer ü Separator : Polyester Tape ü Outersheath : EBXL- EM 104 Black colour or as per customer order. 0 0 ü Temperature Range : -40 C to +90 C. ü Rated Voltage : 300V AC 450V DC ü Specification :BS EN 50306-4 : 2020, Table 1 Class P ü Hazard Level Classification as per EN 45545-2, HL3 Conductor : BS EN 50306-2 : 2020 In addition to BS EN 50306 spec, cables also meet fire performance tests as per UNI CEI 11170-3, DIN 5510-2,NF F 16-101 NFPA -130, EN 45545 2D View Features ü Excellent resistance to high and low temperature ü Outstanding Flame retardant ü Halogen free ü Thin walled with excellent flexibility ü Resistance to oil, fuel, ozone and weathering. ü Easy to strip ü Low smoke density ü Soldering iron resistant ü Electron Beam Cross Linked. ü Resistance to corona effect. www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. Catalogue No. R553 R5530602 R5530603 R5530604 R5530607 R5530613 R5530619 R5530637 R5530802 R5530803 R5530804 R5530807 R5530813 R5530819 R5530837 R5530848 R5531002 R5531003 R5531004 R5531007 R5531013 R5531019 R5531037 28 38 42 60 106 150 261 37 44 53 78 144 202 373 478 42 53 64 97 175 251 467 3.5 3.8 4.1 4.9 7.3 8.1 10.8 4.0 4.2 4.6 5.5 8.2 9.0 12.2 13.9 4.3 4.6 4.9 6.0 8.7 9.8 13.3 40.1 40.1 40.1 40.1 40.1 40.1 40.1 26.7 26.7 26.7 26.7 26.7 26.7 26.7 26.7 20.0 20.0 20.0 20.0 20.0 20.0 20.0 19 X 0.18 19 X 0.18 19 X 0.18 19 X 0.18 19 X 0.18 19 X 0.18 19 X 0.18 37 X 0.16 37 X 0.16 37 X 0.16 37 X 0.16 37 X 0.16 37 X 0.16 37 X 0.16 37 X 0.16 37 X 0.18 37 X 0.18 37 X 0.18 37 X 0.18 37 X 0.18 37 X 0.18 37 X 0.18 1.45 1.45 1.45 1.45 1.45 1.45 1.45 1.65 1.65 1.65 1.65 1.65 1.65 1.65 1.65 1.80 1.80 1.80 1.80 1.80 1.80 1.80 0.42 0.42 0.42 0.42 0.56 0.56 0.56 0.42 0.42 0.42 0.42 0.56 0.56 0.56 0.56 0.42 0.42 0.42 0.42 0.56 0.56 0.56 2 X 0.5 3 X 0.5 4 X 0.5 7 X 0.5 13 X 0.5 19 X 0.5 37 X 0.5 2 X 0.75 3 X 0.75 4 X 0.75 7 X 0.75 13 X 0.75 19 X 0.75 37 X 0.75 48 X 0.75 2 X 1 3 X 1 4 X 1 7 X 1 13 X 1 19 X 1 37 X 1 No. of cores x Cross Section 2 (Nos) x (mm ) Conductor Construction No.of Strands x Strand dia. (Nos x mm) Max. Conductor 0 Resistance at 20 C ( Ω /km) 4.5 4.8 5.3 6.1 8.5 9.3 12.2 5.0 5.2 5.8 6.6 9.4 10.4 13.6 15.7 5.3 5.6 6.1 7.2 10.1 11.2 14.7 11 Siechem EN 50306- 4 1P 300V 4 X 0.5 MM 90 ü For mechanically protected installation in Rail / Bus and other transport vehicles. ü Cables are used in Driver desks, Control panels, wiring harness in inside/outside the moving vehicles. (Min) (Max) Progress throughResearch R TUV ** Certifications Approvals Accreditations ResearchDesign&StandardsOrganisation
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=