Rolling Stock
Catalogue No. 567 www.siechem.com All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. 39 Application Product Construction Technical Data 2D View Wires & Cables Cross Section 2 (mm ) Part Number Cable Weight (Kg/Km) approx. Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11 Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21 Siechem BS EN 50382-2 3.6kV 1 x 240 F 120 * 56716XX 56719XX 56723XX 56727XX 56728XX 56730XX 56732XX 56734XX 56737XX 56738XX 56741XX 56742XX 56744XX 56746XX 56748XX 56749XX Insulation Thickness (mm) (Nom) 50 X 0.25 56 X 0.30 84 X 0.30 80 X 0.40 126 X 0.40 196 X 0.40 276 X 0.40 396 X 0.40 360 X 0.50 475 X 0.50 608 X 0.50 756 X 0.50 925 X 0.50 1221 X 0.50 1525 X 0.50 2013 X 0.50 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 Conductor Construction No.of Strands x Strand dia. (Nos x mm) Features ü Specification : BS EN 50382-2 : 2008 ü Hazard Level Classification as per EN 45545-2, HL3 ü Test voltage : 11kV ü Rated Voltage : 3.6/6kV 0 ü Max. Operating temperature : 120 C ü Type F as per BS EN 50382-2 F : EI 111(Insulation Material) ü Cables also meet fire performance tests as per DIN 5510-2, BS 6853, NFPA -130, NF F 16-101 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.1 3.1 3.2 3.4 3.4 3.4 ü Conductor : Annealed Tinned Copper Class 5 Conductor as per EN 60228 ü Insulation : EI 111 (Silicone) with properties according to BS EN 50382-1 (Min) (Max) 7.6 8.1 9.0 9.5 10.5 11.8 13.0 14.4 16.1 17.5 19.3 20.8 22.6 25.4 27.7 30.8 8.9 9.5 10.6 11.1 12.3 13.8 15.2 16.9 18.9 20.5 22.6 24.4 26.5 29.8 32.4 36.0 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654 0.0495 78 97 120 169 232 322 418 559 744 994 1220 1487 1794 2277 2775 3610 ü Recommended for high temperature applications in railway vehicles (locomotives, trains, trolley buses) ü Used as power and control cables for protected installation inside & outside of rolling stock ü Used in auxillary & main circuit wiring such as control panels, monitoring control, electric heating, lighting etc. Max. Conductor Resistance 0 at 20 C ( Ω /km) Overall Diameter (mm) ü Halogen free. ü Flame retardant. ü Oil resistant. ü Low temperature resistant. ü Excellent flexibility. ü Low smoke density. ü Resistance to ozone, chemical oil and fuel. ü ** We have obtained various approvals, accreditations, and certifications — some of which may not be relevant to this catalog. Progress throughResearch R TUV ** Certifications Approvals Accreditations ResearchDesign&StandardsOrganisation
Made with FlippingBook
RkJQdWJsaXNoZXIy NDgyMjA=