Siechem
SINGLE AND MULTICORE FLEXIBLE CABLES
Siechem flexible cables are manufactured with 100 % pure electrolytic grade bright annealed bare copper wires having 102 % conductivity and
insulated with specially formulated in house PVC compound with high insulation resistance and dielectric strength. Incase of Multi core cables,
the insulated cores are laid up to form the core assembly. Sheathing is provided with specially formulated in house PVC compound to facilitate
easy stripping and also to with standmechanical abrasion.
The insulation and sheathing compounds have a high oxygen and temperature index. The Single and Multicore flexible cables are manufactured
as per IS 694 : 1990 in sizes from0.5
sq.mmto 300
sq.mmin single core and in size 0.5 to 4
sq.mminmulti core construction. These sizes carry the
ISI mark and the remaining sizes generally conform to IS 694 : 1990. Cables as per BS EN 50525-2-31:2011 and BS 6004:2000 BS 6004 are also
manufactured for export market.
Colours : Red, Yellow, Blue, Black, Green, Yellow-Green &Grey Packing : 100m coils in cartons upto 6
sq.mmfor single core cable.
0
Note : HR PVC 105 C rated - data available on request
# Test not applicable for PVC & FR PVC cables. EBXL ZHLS / HFFR PW 125 cables are offered as per international standard.
Size
(Sq.mm)
0.5 16/0.2
0.6
2.6
39.0
4
5
21
0.75 24/0.2
0.6
2.8
26.0
7
9
24
1
32/0.2
0.6
3.0
19.5
12
14
29
1.5 30/0.25
0.6
3.4
13.3
16
19
36
2.5 50/0.25
0.7
4.1
7.98
22
26
49
4
56/0.3
0.8
4.8
4.95
29
35
66
6
84/0.3
0.8
5.3
3.30
37
44
85
10 140/0.3
1.0
7.0
1.91
51
61
121
16 126/0.4
1.0
8.1
1.21
68
83
163
25 196/0.4
1.2
10.2
0.780
86
105
219
35 276/0.4
1.2
11.7
0.554
110
135
272
50 396/0.4
1.4
13.9
0.386
145
178
344
70 360/0.5
1.4
16.0
0.272
215
264
439
95 475/0.5
1.6
18.2
0.206
260
318
523
120 608/0.5
1.6
20.2
0.161
305
374
621
150 756/0.5
1.8
22.5
0.129
355
435
723
185 925/0.5
2.0
24.9
0.106
415
508
825
240 1221/0.5
2.2
28.4 0.0801
500
613
996
300 1525/0.5
2.4
31.0
0.0641
585
717
1150
No. Of Wires /
Wire dia of
Conductor
(mm)
TABLE - 1
Nominal
Insulation
thickness
(mm)
Max.Overall
Cable diameter
(mm)
Max. DC
resistance at
0
20 C
(Ohm/Km)
PVC/FR/FRLS
Current inAmps
Other Brand
HFFR
HEAD OFFICE
FACTORY
26/27, Errabalu Chetty Street,
Chennai - 600 001. India.
RS 104/8 & 105/7, Sedarapet Main Road,
Pondicherry - 605 101. India.
Tel :
+91 44 2522 6141
/ 2522 0859
Fax :
+91 44 2522 2871
Email :
sales@siechem.comWeb :
www.siechem.comTel :
+91 413 2671 070
/ 2671 071
Fax :
+91 413 2671 072
Email :
admn@siechem.comWeb :
www.siechem.comTECHNICAL DATA
S.No.Details
As per IS : 694
PVC - FR
Siechem EBXL
o
ZHLS+HR+FR+125C
PW 125
1
2
3
4
5
6
7
8
9
10
11
Working Voltage
Operating Temp
Short Circuit Temp
Test Voltage
Oxygen Index
Temperature Index
Smoke Emission
#
Toxicity Index
Halogen /Acid Gas Emission
#
Flammability
Soldering Iron Test
1100 V
0
0
-5 to +70 C
0
160 C
3 kV for 5 mins
> 29%
0
> 250 C
NA
NA
<20 % by wt
IS 10810-53
NA
1100 V
0
0
-5 to +70 C
0
160 C
3 kV for 5 mins
3+
0
> 250 C
< 60 %Absorption
NA
<20 % by wt
IS 10810-53
NA
FRLS
(FR-LSH)
1100 V
0
0
-5 to +85 C
0
160 C
3 kV for 5 mins
0
> 250 C
>80 %
High
> 25 %
IS 10810-53
NA
1100 V
0
0
-40 to +90 C
0
160 C
3 kV for 5 mins
> 29%
0
> 250 C
< 20 %
< 3
Nil
IS 60332 P1
NA
1100 V
0
0
-40 to +125 C
0
300 C
3 kV for 10 mins
> 31%
0
30
0 C
< 5 %Absorption
< 3
Nil
IS60332P1 /IEC60754-1, EN 50267-2-1
IEC 60754-2, EN 50267-2-3
IEC 61034-2, EN 50268-2
HR PVC
Pass
Market HFFR
All information given are in good faith. Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing &
Siechem shall not be liable for any compensation for losses or any damages even if contracted terms say otherwise. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to
ChennaiJurisdiction.
Siechem EBXL
o
ZHLS+HR+FR+125 C
PW 125
3+
Additional Tests
Table - 2
Soldering Iron Test
o
Acceleration Ageing @240 C
Varnish Test
Cable found sticking to the conduit over a
period of time and becomes non separable.
Non-sticking, so the cable can be
pulled out for rewiring at later date from conduit.
Fail
Fail
Fail
Fail
Pass
-
-
-
-
-
No. of Cores
De-rating Factor
1
4
2
5
3
6 7
10
14
8
12
16 19
1.00
0.65
0.80
0.60
0.70
0.57 0.55
0.48
0.43
0.52
0.45
0.41 0.38
Nominal
Area
Sq.mm
0.5
0.75
1.0
1.5
2.5
4
6
10
16
25
35
50
70
95
120
No./mm
16/0.2
24/0.2
32/0.2
30/0.25
50/0.25
56/0.3
84/0.3
140/0.3
126/0.4
196/0.4
276/0.4
396/0.4
360/0.5
475/0.5
608/0.5
mm
0.6
0.6
0.6
0.6
0.7
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
ohm/km
39.0
26.0
19.5
13.3
7.98
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
0.9
0.9
0.9
0.9
1.0
1.0
1.1
1.3
1.4
1.4
1.6
2.0
2.2
2.4
2.5
2C 3C 4C 5C 6C 7C
mm / mm
8C 10C 12C 14C 16C 19C
0.9
0.9
0.9
0.9
1.0
1.0
1.2
1.4
1.4
1.5
1.6
2.0
2.2
2.4
2.5
0.9
0.9
0.9
1.0
1.0
1.0
1.2
1.4
1.4
1.6
1.7
2.0
2.2
2.4
2.5
0.9
0.9
1.0
1.0
1.0
1.1
0.9
1.0
1.0
1.0
1.1
1.2
0.9
1.0
1.0
1.0
1.1
1.2
1.0
1.0
1.0
1.1
1.2
1.4
1.0
1.1
1.1
1.1
1.3
1.4
1.0
1.1
1.1
1.1
1.3
1.4
1.1
1.1
1.1
1.2
1.3
1.4
1.1
1.2
1.2
1.2
1.4
1.5
1.1
1.2
1.3
1.3
1.4
1.5
6.9
7.3
7.6
8.9
10.3
11.6
13.0
16.5
19.4
23.8
27.2
32.0
36.8
41.8
46.2
7.3
7.7
8.1
9.4
10.9
12.4
13.8
17.69
20.6
25.6
29.3
34.6
39.6
47.0
51.0
8.0
8.4
8.8
10.4
12.0
13.6
15.47
19.5
23.0
28.5
32.7
38.6
44.3
50.2
55.7
8.7
9.2
9.6
11.4
13.2
15.3
9.5
10.0
10.5
12.4
14.5
16.2
9.5
10.0
10.5
12.4
14.5
16.2
11.1
11.8
12.4
14.7
17.3
17.2
12.0
12.7
13.4
16.0
18.7
19.7
12.4
13.1
13.9
16.5
19.4
20.8
13.1
13.8
14.6
17.4
20.5
22.7
13.8
14.6
15.4
18.4
21.7
24.3
14.6
15.4
16.3
19.5
23.8
25.8
No. of
strands /
Nom. Wire
dia
Nom.
Insulation
thickness
Current Rating : De-rating factor for cable bunching will apply as per Table 2
Nominal Sheath thickness /
Maximum Overall diameter
Max. DC
Conductor
resistance
0
at 20 C
Siechem
Wires & Cables
Amp
4
7
12
16
22
29
37
51
68
86
110
145
215
260
305
Current rating
for single
core cable
@ ambient
Temp. 40°C &
operating
Temp. 70°C
ISO/TS
22163
AS
9100
ISO
45001
DGQA
TUV
RDSO
IHQ
IndianNavy
ISO
9001
IATF
16949
ISO
14001
ESMA
IRS
Approvals & Licenses