Home >
Products >
Nuclear Cables >
Siechem ATC Conductor, EBXL-XLPE Dual Wall Insulated 600 V rated cable as per UL Type RHH / RHW-2
More Category
Aerospace Cables
Airport Lighting Cables
Appliance Wires & Cables
Automotive Cables
Battery Cables
Building Wires
Composite/Hybrid Cables
Control & Switchboard Cables
Diamond Colourisation
Fibre Optic Cables & Accessories
Fire Resistant Cables
Flexible Cables
Heat Shrinkable Products
High Temperature Cables PW 125, Sietherm 125, Sietherm 155 & Fluoro 200
Instrumentation Cables
Irrigation Communication Cables
Jelly Filled Telecom Cables
Linear Heat Detection Cable
Mining Cables
Nuclear Cables
Offshore, Marine, Shipboard & Boat Cables
Oil & Gas, Petrochemical Cables
Power Cables
Power Cords
PW 125 Wires for High rise building & Panel Wiring
Railway Quad & Signalling Cables
Rolling Stock Cables For Electric & Diesel Train
Rubber Cables
Silicone Cables
Soft Drawn Bare Copper Conductor
Solar Cables
TEFLON, ETFE, PTFE, FEP, PFA, PEEK, PVDF & KAPTON Cables
Telecommunication Cables
Tri-rated Cables
Welding Cables
Wind Energy Cables
Wiring Harness
Cables by Standard
Nuclear Cables
Siechem ATC Conductor, EBXL-XLPE Dual Wall Insulated 600 V rated cable as per UL Type RHH / RHW-2
Power Cable is a 600 V, insulated dual wall, single conductor class IE rated wire construction specifically designed for application in nuclear generating station and where additional jacketing protection is required.
For use in Class IE low voltage Power and lighting functions where optimum
performance is required.
May be installed in trays, conduit, ducts, or direct buried
Conductor : Annealed Tinned copper as per ASTM B33
Insulation : Flame retardant, heat- moisture & radiation- resistant, thermoset Cross Linked Polyethylene (EBXL-XLPE 120oC).
Rated Voltage : 600 V
Temperature Rating :120°C
Specification :
Specification : (1) UL 44 RHH/RHW-2
(2) Class IE Qualified in accordance with
IEEE 323-1974 and IEEE 383-1974
(3) ICEA S-95-658 (formerly ICEA S-66-
524 & S-19-81)
Rated at 90°C wet or dry
Fully traceable
Qualified for 40-year service life
Radiation resistant (up to 200 megarads)
Long-term moisture and radiation stability
Long-term thermal endurance and superior electrical
Excellent mechanical cut through properties
Free stripping for ease of termination
Meets cold bend test at -40oC
Part Number
Cond Size
Cond Strand
Insulation Thickness (Nom.)
Jacket Thickness
Cable Diameter
(Nom.)
Copper Index (approx.)
Cable Weight (approx.)
(AWG)
mm
mm
mm
kg/km
kg/km
953 79 XX
14
7/0.615
0.76
0.38
4.19
19
34
953 78 XX
12
7/0.775
0.76
0.38
4.67
30
48
953 77 XX
10
7/0.978
0.76
0.38
5.26
48
69
953 76 XX
8
7/1.234
1.14
0.38
6.81
76
112
953 75 XX
6
7/1.554
1.14
0.76
8.53
121
177
953 74 XX
4
7/1.961
1.14
0.76
9.73
192
260
953 73 XX
2
7/2.474
1.14
0.76
11.2
305
388
953 72 XX
1
19/1.687
1.40
1.14
13.5
384
506
953 90 XX
1/0
19/1.892
1.40
1.14
14.5
485
620
953 91 XX
2/0
19/2.126
1.40
1.14
15.6
612
760
953 92 XX
3/0
19/2.388
1.40
1.14
16.9
771
935
953 94 XX
4/0
19/2.68
1.40
1.14
18.3
972
1154
953 41 XX
250
37/2.088
1.65
1.65
21.1
1149
1410
953 44 XX
350
37/2.471
1.65
1.65
23.7
1609
1911
953 46 XX
500
37/2.951
1.65
1.65
27.0
2297
2653
953 49 XX
750
61/2.817
2.03
1.65
32.3
3446
3915
953 50 XX
1000
61/3.251
2.03
1.65
36.1
4595
5131