- Low-tension electric wire for automobiles.
- Used in Motorcycles and other motor vehicles for starting, charging, lighting, signal and instrument panel circuits.
| Part Number |
Conductor Construction | Insulation Wall Thickness Nom |
Cable | Max. Conductor Resistance at 200C |
Current Carrying capacity |
StandardLength* | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| Nominal Cross- Section |
No. of Strands |
Diameter of Single wire Max. |
Conductor Diameter Max. |
Overall Diameter Max/Min |
Weight Approx |
|||||
| mm2 | nos. | mm | mm | mm | mm | kg/km | Ω/km | Amps | mtrs | |
| Y80205XX** | 0.35 | 12 | 0.21 | 0.9 | 0.25 | 1.20/1.40 | 5 | 54.4 | 12 | 500 |
| Y80206XX | 0.50 | 16 | 0.21 | 1.1 | 0.28 | 1.40/1.60 | 7 | 37.1 | 15 | 500 |
| Y80208XX | 0.75 | 24 | 0.21 | 1.3 | 0.30 | 1.70/1.90 | 10 | 24.7 | 20 | 500 |
| Y80210XX | 1 | 32 | 0.21 | 1.5 | 0.30 | 1.90/2.10 | 11 | 18.5 | 24 | 500 |
| Y80213XX | 1.5 | 30 | 0.26 | 1.8 | 0.30 | 2.20/2.40 | 17 | 12.7 | 30 | 500 |
| Y80214XX | 2 | 28 | 0.31 | 2.0 | 0.35 | 2.50/2.80 | 23 | 9.42 | 37 | 500 |
| Y80216XX | 2.5 | 50 | 0.26 | 2.2 | 0.35 | 2.70/3.00 | 25 | 7.60 | 42 | 500 |
| Y80217XX | 3 | 44 | 0.31 | 2.4 | 0.40 | 3.10/3.40 | 35 | 6.15 | 49 | 500 |
| Y80219XX | 4 | 56 | 0.31 | 2.8 | 0.40 | 3.40/3.70 | 43 | 4.71 | 58 | 500 |
| Y80221XX | 5 | 65 | 0.33 | 3.1 | 0.40 | 3.90/4.20 | 54 | 3.94 | 66 | 500 |
| Y80223XX | 6 | 84 | 0.31 | 3.4 | 0.40 | 4.00/4.30 | 59 | 3.14 | 75 | 500 |
| Y80225XX | 8 | 50 | 0.46 | 4.3 | 0.40 | 4.60/5.00 | 82 | 2.38 | 92 | 500 |
| Y80227XX | 10 | 80 | 0.41 | 4.5 | 0.60 | 5.30/6.00 | 105 | 1.82 | 107 | 500 |
| Y802A11XX | 12 | 96 | 0.41 | 5.4 | 0.60 | 5.80/6.50 | 135 | 1.52 | 122 | 500 |
| Y80228XX | 16 | 126 | 0.41 | 5.8 | 0.65 | 6.40/7.20 | 167 | 1.16 | 142 | 500 |
| Y80256XX | 20 | 152 | 0.41 | 6.9 | 0.65 | 7.00/7.80 | 208 | 0.995 | 158 | 500 |
| Y80230XX | 25 | 196 | 0.41 | 7.2 | 0.65 | 7.90/8.70 | 245 | 0.743 | 184 | 500 |
| Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering. | |||
| Red – 01 | Yellow – 02 | Blue – 03 | Black – 04 |
| Green – 05 | Yellow-Green – 06 | Grey – 07 | Brown – 08 |
| White – 09 | Orange – 10 | Violet – 11 | Chocolate – 12 |
| Tan – 13 | Charcoal – 14 | LT Blue – 15 | DK Grey – 16 |
| LT Green – 17 | DK Green – 18 | DK Blue – 19 | Purple – 20 |
| Pink – 21 | |||
Other length as per Customer order.
Current Carrying capacity given is for the maximum conductor operating temperature of 80°C and ambient air temperature of 40°C.