| Part Number |
Conductor Construction | Cable | Weight Approx. |
Max. Conductor Resistance at 20°C |
Current Carrying Capacity |
Standard Length* |
||||
|---|---|---|---|---|---|---|---|---|---|---|
| Nominal Cross- Section |
No. of Strands |
Diameter of Single wire max. |
Conductor Diameter Max. |
Insulation Wall Thickness Nom |
Overall Diameter Min/Max |
|||||
| D28308XX | 0.75 | 7 | 0.38 | 1.3 | 0.24 | 1.7/1.9 | 5 | 43.6 | 15 | 500 |
| D28310XX | 1.00 | 7 | 0.43 | 1.5 | 0.24 | 1.9/2.1 | 6 | 32.7 | 18 | 500 |
| D28312XX | 1.25 | 19 | 0.30 | 1.7 | 0.24 | 2.1/2.3 | 7 | 26.3 | 21 | 500 |
| D28313XX | 1.50 | 19 | 0.32 | 1.8 | 0.24 | 2.2/2.4 | 8 | 22.4 | 23 | 500 |
| D28314XX | 2.00 | 19 | 0.37 | 2.0 | 0.28 | 2.5/2.8 | 10 | 16.6 | 28 | 500 |
| D28316XX | 2.50 | 19 | 0.43 | 2.2 | 0.28 | 2.7/3.0 | 12 | 13.4 | 32 | 500 |
Other length as per Customer order.
Current Carrying Capacity given is for the maximum conductor operating temperature of 125°C and ambient temperature of 40°C.