| Part Number |
Conductor Construction | Cable | Min. Outersheath thickness | Overall Diameter Min/Max | Weight Approx. |
Max. Conductor Resistance at 20°C |
Standard Length* |
||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Nominal Cross- Section |
No. of Strands |
Diameter of Single wire max. |
Conductor Diameter Max. |
Insulation Wall Thickness Nom |
Overall Diameter Min/Max |
||||||
| D2460502 | 2×0.35 | 7 | 0.27 | 0.90 | 0.25 | 1.4/1.6 | 0.42 | 3.8/4.2 | 19 | 54.4 | 500 |
| Insertion loss : dB/Km | ||||||||||
| At 5 MHz | At 10 MHz | At 15 MHz | At 20 MHz | At 25 MHz | At 50 MHz | |||||
| <82 dB/Km | <140 dB/Km | <195 dB/Km | <245 dB/Km | <290 dB/Km | <500 dB/Km | |||||
Other length as per Customer order.
Current Carrying Capacity given is for the maximum conductor operating temperature of 105°C and ambient temperature of 40°C.