Menu

Products

More Category
Cables by Segment

Automotive Cables

ATEEX

  • High voltage and high current circuit in electric vehicles.
  • High reliability
  • Low cost
  • High ecological solution

  • Conductor : Soft-annealed electrolytic copper E-Cu ETP1 according to JIS C 3102, tinned conductor construction.
  • Insulation : Electron beam cross linked polyethylene
  • Colour : As per customer order.
  • Single core

  • Temperature Range : – 40°C to +120°C (3000 hours)
  • Standard : ISO 6722
  • Test Voltage : 5 kV for 5 minutes
  • A : Automobiles
  • T : Tinned annealed copper wire
  • E : Electric Automobile
  • EX : Halogen free irradiated cross-linked Polyethylene (Insulation)

  • Flame retardant
  • Highly resistant against acids, Iyes, petrol and diesel.
  • Flexible conductor with Electron beam cross linked polyethylene thin wall insulation for smaller diameter and lesser weight.
  • Heat resistant

Part
Number
Conductor Construction Insulation Wall Thickness Nom. Cable Max.
Conductor Resistance at 20°C
Current Carrying Capacity Standard Length*
Nominal Cross Section No. of Strands Diamter of Single wire max. Conductor Diameter Max. Overall Diameter Weight Approx.
Nom. Max.
mm2 nos. nos. mm mm mm mm mm Ω/km Amps mtrs
B731A11XX* 12 154 0.33 5.40 1.0 6.1 7.4 130 1.60 119 1000
B73155XX 15 171 0.33 5.70 1.0 7.6 8.0 150 1.44 131 1000
B73156XX 20 247 0.33 6.90 1.1 8.1 9.10 205 0.999 159 1000
B73157XX 30 361 0.33 8.30 1.3 9.7 10.9 300 0.684 200 500
B73158XX 40 494 0.33 9.60 1.4 11.2 12.4 405 0.500 241 500
B73134XX 50 798 0.30 10.50 1.5 11.5 13.5 535 0.375 283 500

 

Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red – 01 Yellow – 02 Blue – 03 Black – 04 Green – 05 Yellow-Green – 06 Grey – 07 Brown – 08 White – 09 Orange – 10 Violet – 11
Chocolate – 12 Tan – 13 Charcoal – 14 LT Blue – 15 DK Grey – 16 LT Green – 17 DK Green – 18 DK Blue – 19 Purple – 20 Pink – 21

Other length as per Customer order.

Current Carrying Capacity given is for the maximum conductor operating temperature of 120°C and ambient temperature of 40°C.