FLALR2X-A

  • Wire harness of low-tension electric circuits for automobiles.
  • Used in motorcycles and other motor vechicles for starting, charging, lighting, signal and instrument panel circuits.
  • Especially used for circuits requiring heat resistance.

  • Conductor : Aluminium alloy conductor, EAL 99, 7 acc to EN 573-3, (Symmetrical structure A).
  • Insulation : EBXL-XLPE, (Reduced wall thickness).
  • Colour : As per customer order.

  • Temperature Range : -40°C to +125°C (3000 Hours).
  • Voltage : 60V.
  • Min. Bending radius : 5 x Cable OD.
  • FL : Automotive cable.
  • AL : Aluminium.
  • R : Reduced wall thickness.
  • 2X : PE-X (Polyethylene cross-linked).
  • A : Structure A.
  • Standard : ISO 19642-4, LV 112-2.

  • Electron beam cross linked.
  • Flame retardant.
  • Highly resistant against acids, alkaline, petrol and diesel.
  • Extra flexibility.
  • Light weight.
  • Excellent resistance to oil and flame.
  • RoHS.

Part
Number
Conductor Construction Cable Weight
Approx.
Max.
Conductor Resistance at 20°C
Current
Carrying
Capacity
Standard
Length*
Nominal
Cross-
Section
No. of
Strands
Diameter of
Single wire
max.
Conductor
Diameter Max.
Insulation
Wall Thickness
Nom
Overall
Diameter
Min/Max
D30708XX 0.75 7 0.38 1.3 0.24 1.70/1.90 4.0 43.6 19 500
D30710XX 1.00 7 0.43 1.5 0.24 1.90/2.10 5.0 32.7 24 500
D30712XX 1.25 19 0.30 1.7 0.24 2.10/2.30 5.5 26.3 27 500
D30713XX 1.50 19 0.32 1.8 0.24 2.20/2.40 6.5 22.4 30 500
D30714XX 2.00 19 0.37 2.0 0.28 2.50/2.50 9.0 16.6 37 500
D30716XX 2.50 19 0.43 2.2 0.28 2.70/3.00 11.0 13.4 42 500
Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red – 01 Yellow – 02 Blue – 03 Black – 04 Green – 05 Yellow-Green – 06 Grey – 07 Brown – 08 White – 09 Orange – 10 Violet – 11
Chocolate – 12 Tan – 13 Charcoal – 14 LT Blue – 15 DK Grey – 16 LT Green – 17 DK Green-18 DK Blue – 19 Purple – 20 Pink – 21

Other length as per Customer order.

Current Carrying Capacity given is for the maximum conductor operating temperature of 125°C and ambient temperature of 40°C.