More Category
- 3 GKW
- 4 GKW
- 9 GKW
- Aerospace Cables
- Airport Lighting Cables
- Appliance Wires & Cables
- AS/NZS 5000-1 & 2
- AS/NZS 5000-3
- AS/NZS Standard Cable
- Automotive Cables
- Battery Cables
- BS 3G 210
- BS 3G 233
- BS 5308-Part 1 & 2
- BS 5467
- BS 6004
- BS 6007
- BS 6141
- BS 6231
- BS 6346
- BS 638-Part 4
- BS 6500
- BS 6724
- BS 6862 Part-1
- BS 7211 : 2012
- BS 7629-1-Amendment 1
- BS 7846
- BS 7919
- BS EN 50264
- BS EN 50288-7
- BS EN 50306
- BS EN 50382
- BS EN 50525-2-11
- BS EN 50525-2-12
- BS EN 50525-2-21
- BS EN 50525-2-22
- BS EN 50525-2-31
- BS EN 50525-2-41
- BS EN 50525-2-51
- BS EN 50525-2-81
- BS EN 50525-3-11
- BS EN 50620
- BS EN Standard Cable
- BS Standard Cable
- Building Wires
- Cables by Segment
- Cables by Standard
- CLW Standard Cable
- CLW/ES/3/0458
- CLW/ES/3/0459
- Composite/Hybrid Cables
- Control & Switchboard Cables
- Def Stand 61-12 Part 33
- DEF Standard Cable
- Def-Stand 02-517 Part 1 / Issue 2
- Def-Stand 02-517 Part 2 / Issue 2
- Diamond Colourisation
- DIN 72551-6 Cable
- EDPS 179 & EDPS 304 Cable
- EDTS 132 Cable
- EED 50-12 Rev 2
- EED 50-13 Rev-1
- EED Standard Cable
- ELRS/SPEC/ELC/0019 Cable
- ES-AU5T-1A348-AA Cable
- ES91110-05 Cable
- ESF-M1L59-A Cable
- Fibre Optic Cables & Accessories
- Fire Resistant Cables
- Flexible Cables
- GKW
- GKW Cable
- GR/CUG-01/03 Cable
- GS 95007-1 BMW Cable
- Heat Shrinkable Products
- High Temperature Cables PW 125, Sietherm 125, Sietherm 155 & Fluoro 200
- IEC 60092-350
- IEC 60092-353
- IEC 60092-375
- IEC 60092-376
- IEC 60227 - 3
- IEC 60227 - 4
- IEC 60227 - 5
- IEC 60227 - 6
- IEC 60227 - 7
- IEC 60245 - 3
- IEC 60245 - 4
- IEC 60245 - 6
- IEC 60502 Part-1
- IEC Standard Cable
- Instrumentation Cables
- Irrigation Communication Cables
- IRS S 63-Rev 04
- IRS S 76-89
- IRS Standard Cable
- IS 14494
- IS 1554-1
- IS 2465 Cable
- IS 2593
- IS 694
- IS 7098-Part 1
- IS 9857
- IS 9968 Part-1
- IS Standard Cable
- ISO 6722-1, LV 216-2, ISO 19642-5 & ISO 19642-9
- JASO D 608
- JASO D 611-94
- JASO Standard Cable
- Jelly Filled Telecom Cables
- JIS C 3406 Cable
- Linear Heat Detection Cable
- MIL Standard Cable
- MIL STD 1916
- MIL W 16878/4C
- MIL W 22759 E
- MIL-C-27500G
- MIL-C-7078/2
- MIL-W-81044B
- Mining Cables
- MOD 02 512-NES 512 Part-2
- MOD 02 512-NES 512 Part-3
- MOD 02 526
- MOD 527-NES 527
- MOD NES 517
- NEMA WC 27500
- NES 525
- NES Standard Cable
- Nuclear Cables
- Offshore, Marine, Shipboard & Boat Cables
- Oil & Gas, Petrochemical Cables
- Power Cables
- Power Cords
- PW 125 Cable
- PW 125 Wires for High rise building & Panel Wiring
- Railway Quad & Signalling Cables
- Rolling Stock Cables For Electric & Diesel Train
- Rubber Cables
- SAE AS22759/32 - 35
- SAE AS81044/12
- SAE J 1127
- SAE J 1128
- SAE J 1678
- SAE J 1939/11
- SAE J 1939/15
- SAE Standard Cable
- Sietherm 125 Cable
- Sietherm 155 Cable
- Silicone Cables
- Soft Drawn Bare Copper Conductor
- Solar Cables
- TEFLON, ETFE, PTFE, FEP, PFA, PEEK, PVDF & KAPTON Cables
- Telecommunication Cables
- Tri-rated Cables
- TUV 2Pfg1169/08.2007 & EN 50618 Cable
- TW Cables
- UL & CSA Standard Cable
- UL/ETA/CSA Standards Cables
- VDE 0245 / 0250 / 0281 / 0282
- VDE 0250
- VDE 0250 - 602
- VDE 0250 - 606
- VDE 0250 - 812
- VDE 0250 / 0281
- VDE 0250-1
- VDE 0282
- VDE Standard Cable
- VG 95218 Part-63
- VG 95218-Part-51
- VG 95218-Part-62
- VG 95218-Part-66
- VG Standard Cable
- Volvo 1052501 001-RK
- Volvo 1052521 005-R2
- Volvo 1058473 005-RXKB
- Volvo R4 Cables-ISO 6722
- Volvo Standard Cable
- VW 603 06 Cable
- Welding Cables
- Wind Energy Cables
- Wiring Harness
- YPES Cable
- YPES-11-01-115
- YPES-17-21-004
- YPES-17-21-005
Cables by Segment
Cables by Standard
Automotive Cables
1.5D-EXHV-AS
- Used for car antenna cable and feeder cable.
- Automotive inner Wiring for communication and Electronic Devices.
- Automotive TV/Radio.
- Drop Wire, House wiring to indoor.
- Monitoring/Security Camera.
- Ringing circuit connection between high frequency apparatus.
- Conductor : Annealed Tinned Copper Conductor
- Insulation : XLPE
- Insulation Color : Natural
- Taping : Al – Mylar tape
- Braiding : ATC
- Sheath : Polyvinylchloride
- Sheath Color: As per customer request
- Standard : ES 96220-01
- Characteristic Impedance : 50 ± 2 Ohm
- Electrostatic Capacity : 104 ± 5 nF/km
- Min.Insulation Resistance : 1000 MΩ.km
- Max Attenuation : 900 MHz 0.76 dB/m
- 1500 MHz 1.04 dB/m
- 1600 MHz 1.08 dB/m
- 1900 MHz 1.20 dB/m
- 2000 MHz 1.23 dB/m
- 2500 MHz 1.40 dB/m
- 3000 MHz 1.59 dB/m
- Low Loss.
- Characteristic Impedance is constant in high frequency domain.
- We are superior in flexibility workability after being lightweight.
- It is high cover,low loss type.
Part
Number |
Conductor Construction |
Insulation
Wall Thickness
(Min./Nom.) |
Al Mylar
Tape
Thickness
(Nom.) |
Braiding Wire Dia (Nom) |
Outer Sheath
Thickness
(Min./Nom.) |
Overall
Diameter (Nom) |
Weight
Approx |
Max.
Conductor
Resistance at 20°C |
Nominal
Cross-
Section |
No. of
Core |
No. of Strands/Stand dia.
(Nom.) |
Diameter of Wire (Nom) |
|
mm |
nos. |
nos./mm |
mm |
mm |
mm |
mm |
mm |
mm |
kg/km |
Ω/km |
H715A030003 |
0.2 |
1 |
7/0.19 |
0.54 |
0.48/0.53 |
0.035 |
0.12 |
0.38/0.43 |
2.90 ± 0.10 |
15 |
110 |